Selection Guide for
未标题-2.png
Selection Guide for
To meet the needs of customers in different application scenarios, our company has developed and produced fully enclosed epoxy resin encapsulated power transformers at different levels, including:
1. "Argent Angel" S series and SL series (flat type) fully enclosed epoxy resin encapsulated power transformers
2. "Blue Fairy" T series and TL series (flat type) fully enclosed epoxy resin encapsulated power transformers
3. "Green Cube" M series toroidal fully enclosed epoxy encapsulated power transformers
General Technical Specifications for Standard Products:

Model Choosing Reference 

for S, SL, T, TL, M &H Series PCB Mount Power Transformers

To meet the needs of customers in different application scenarios, our company has developed and produced Fully-encapsulated PCB Mount Power Transformers at different levels, including:

1. "Argent Angel" S Series and SL Series (flat type) Fully-encapsulated PCB Mounting Power Transformers 


The biggest features of the products of "Argent Angel" S Series and SL Series are good electromagnetic characteristic indicators, high input overvoltage capability (up to +25% to reach 275V), wide environmental adaptability range, and good safety performance



(    certification,    certification,    certification, inter-winding withstands 50Hz 3750V effective value/1 minute), an internal temperature protector is installed. Even in the case of a short circuit in the transformer load, the power supply can be effectively cut off to prevent the equipment from burning out. It is the best supporting choice for customers producing industrial-grade equipment and military-grade products. Because its case is made entirely of silver-gray flame-retardant PBT and PBO engineering plastics, its performance indicators are as excellent as an angel, so it is called "Argent Angel". 

2. "Blue Fairy" T Series and TL Series (flat type) Fully-encapsulated PCB Mounting Power Transformers 



The biggest features of the products of "Blue Fairy" T series and TL series are their relatively small size, high power density, and safety performance not lower than national standards (   certification,   certification, inter-winding withstand 50Hz 2000V effective value/1 minute) and economical prices. It is the best choice for customers producing various civilian products. Because its case is made entirely of sky blue flame-retardant PBT engineering plastics, its small and powerful features are like a little fairy, so it is called "Blue Fairy".

3. "Green Cube" M Series Toriodal Fully-encapsulated PCB Mounting Power Transformers  

The "Green Cube" M Series is a Toriodal encapsulated transformer. Its biggest features are high efficiency, low leakage, good output characteristics, strong EMC capability, high safety performance, and inter-winding withstand 50Hz 4000V/1 minute. An internal temperature protector is installed. Even in the event of a short circuit in the transformer load, the power supply can be effectively cut off to prevent the equipment from burning out. Small in size, light in weight, it is the best supporting choice for customers producing industrial-grade equipment and military-grade products. Because its case is made entirely of green flame-retardant PPO engineering plastics that symbolize environmental protection, its performance indicators especially meet the requirements of "green, environmental protection, energy saving and high efficiency" put forward by the national power industry, and are as superior as if magic has been applied, so it is called "Green Cube". 

4. H Series PCB Mounting Power Transformer


Naming Rules

of Series of S, SL, T, TL, M & H PCB Mounting Power Transformers

 

1Standard Series

image.png 

 

 

 

 

 

 

 

 

 

 

SN

01

01B

02

03

04

05

05B

06

06B

Output Voltage

6V

7.5V

9V

12V

15V

18V

21V

24V

27V

SN

07

07B

08

09

10

11

11B

12

12B

Output Voltage

2×6V

2×7.5V

2×9V

2×12V

2×15V

2×18V

2×21V

2×24V

2×27V

 

 

 

 

2Non-standard series

image.png 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. The products in series S and T with letter “L” following Rated VA code are lower in height than those without “L”.


 

 

 

Tables of Model Choosing Reference

 

0.25-2VA

Power

Model

Over

Input

Voltage

Voltage Regulation Ratio

220V/50Hz Input

Dimension

(mm³)

L×W×H

Weight

(g)

Page

Idle Current

Idle Loss

0.25VA

S0.25

25%

≤26%

≤2.5mA

≤0.10W

26×22.5×23

40

13

0.35VA

S0.35L

15%

≤45%

≤3.5mA

≤0.20W

32.6×27.6×16

40

14

0. 5VA

S0.5

15%

≤30%

≤4.5mA

≤0.3W

26×22.4×26

50

15

T0.5

10%

≤40%

6mA

≤0.25W

26×22.5×23

40

45

T0.5A

10%

40%

10mA

0.5W

23×22×19

36

46

T0.5S

10%

35%

16mA

1.6W

23×22×19

33

47

H0.5

10%

30%

6mA

0.3W

26×22.4×26

50


0.6VA

S0.6

25%

≤38%

≤3mA

≤0.12W

30.5×27.5×20.5

60

16

T0.6

10%

≤39%

≤3.5mA

≤0.16W

30.5×27.5×20.5

60

48

T0.6A

10%

≤40%

8mA

0.5W

22×23×22

45

49

0.8VA

S0.8

25%

≤20%

≤4mA

≤0.20W

30.5×27.5×25

75

17

1VA

S1

25%

≤20%

6mA

≤0.15W

30.5×27.5×25

75

18

S1L

25%

≤23%

≤8mA

≤0.17W

32.6×27.6×22.2

75

19

T1

10%

≤20%

7mA

≤0.29W

30.5×27.5×25

75

50

1.2VA

S1.2

25%

≤16%

≤7mA

≤0.25W

30.5×27.5×31.25

100

20

T1.2L

10%

23%

9mA

≤0.36W

37.5×32×24.5

110


1.3VA

S1.3L

25%

≤17%

≤7.5mA

≤0.26W

43×35×22

110

21

T1.3L

10%

≤18%

≤9mA

≤0.50W

43×35×22

110

51

1.5VA

S1.5

25%

≤17.5%

≤7.5mA

≤0.20W

30.5×27.5×31.25

100

22

S1.5L

25%

≤12.5%

≤8mA

≤0.35W

43×35×24.5

125

23

T1.5

10%

≤23%

≤8.5mA

≤0.35W

30.5×27.5×25

75

52

H1.5

10%

25%

9mA

0.3W

30.8×27.9×28

85


1.6VA

M1.6/MS1.6

10%

30%

≤1.0mA

≤0.08W

39.6×39.6×18.5

80

88

2VA

S2

25%

≤15%

≤7.5mA

≤0.20W

37.5×32×31

125

24

S2L

25%

≤15%

≤8.5mA

≤0.35W

44×36×26.5

135

25

S2S

25%

≤21%

≤12mA

≤0.25W

32.6×27.6×31.25

135

26

T2

10%

≤21%

≤10mA

≤0.40W

30.5×27.5×31.25

100

53

T2A

10%

30%

≤12mA

≤0.40W

30.5×28×32

103

54

 


 

 

3-10VA

Power

Model

Over

Input

Voltage

Voltage Regulation Ratio

220V/50Hz Input

Dimension

(mm³)

L×W×H

Weight

(g)

Page

Idle Current

Idle 

Loss

3VA

S3

25%

≤15%

≤8mA

≤0.25W

37.5×32×35

155

27

SL3

20%

≤25%

≤12mA

≤0.25W

53×43×21.5

165

37

T3

10%

≤22%

17mA

≤0.40W

30.5×27.5×31.25

100

55

T3L

10%

≤22%

≤15.5mA

≤0.50W

43×35×24.5

125

56

T3LD

10%

≤22%

≤15.5mA

≤0.50W

43×35×25

125

57

T3H

10%

≤25%

≤12mA

≤0.45W

33×28×34.2

140

58

T3S

10%

38%

≤15mA

≤0.35W

30.5×27.5×31.25

125


H3

10%

38%

15mA

0.35W

30.5×27.5×31.25

105


3.2VA

M3.2/MS3.2

10%

≤28%

≤1.5mA

≤0.1W

44.7×44.7×19.5

120

89

3.5VA

T3.5

10%

≤21%

≤17mA

≤0.50W

37.5×32×31

125

59

T3.5L

10%

≤20%

≤18mA

≤0.50W

44×36×26.5

135

60

T3.5LD

10%

≤20%

≤18mA

≤0.50W

44×36×26.5

135

61

4VA

S4

25%

≤13%

≤16mA

≤0.50W

45×37×33

195

28

T4

10%

≤18%

≤18mA

≤0.60W

37.5×32×35

155

62

T4L

10%

≤18%

≤18mA

≤0.50W

44×36×26.5

135

63

4.5VA

TL4.5

10%

≤28%

≤26mA

≤0.45W

54.5×44×18

160

78

5VA

S5

25%

≤13%

≤18mA

≤0.35W

45×37×33

195

29

T5

10%

≤15%

≤20mA

≤0.40W

37.5×32×35

155

64

T5L

10%

≤23%

≤18mA

≤0.40W

44×33×29.5

170


T5H

10%

≤25%

≤18mA

≤0.40W

37.5×32.2×35

170


M5/MS5

10%

≤25%

≤2.0mA

≤0.15W

49.7×49.7×19.5

150

90

H5

10%

25%

18mA

0.4W

37.5×32.2×35

170


6VA

SL6

20%

≤24%

≤15mA

≤0.32W

53×43×25.5

220

37

T6

10%

≤16%

≤24mA

≤0.80W

45×37×33

195

65

TL6

10%

28%

 20mA

 0.5 W

58.5×43.5×18.2

170

79

7VA

M7/MS7

10%

≤20%

2.5mA

≤0.2W

49.7×49.7×23.1

180

91

8VA

S8

25%

≤20%

≤20mA

≤0.80W

51×43×33.8

275

30

T8

10%

≤16%

≤28mA

≤0.60W

45×37×33

195

66

T8H

10%

≤16%

≤25mA

≤1.00W

45×37×40

195

67

H8

10%

25%

28mA

0.6W

44×36×35

210


9VA

SL9

20%

≤23%

≤20mA

≤0.43W

53×43×30

280

37

T9

10%

≤21%

18mA

≤0.90W

51×43×33.8

275

68

TL9

10%

≤20%

15mA

≤0.5W

58.5×43.5×22.3

200

80

10VA

S10

25%

≤15%

≤20mA

≤0.65W

51×43×36

300

31

S10D

25%

≤15%

≤20mA

≤0.65W

69×43×38.5

300

32

SL10

15%

≤26%

≤30mA

≤0.75W

68×55×24

290

38

T10

10%

≤13%

≤28mA

≤1.00W

51×43×36

300

69

T10D

10%

≤13%

28mA

≤1.00W

69×43×38.5

300

70

M10/MS10

10%

≤18

3.5mA

≤0.3W

55×55×26

250

92

 

 

 

12-160VA

Power

Model

Over

Input

Voltage

Voltage Regulation Ratio

220V/50Hz Input

Dimension

(mm³)

L×W×H

Weight

(g)

Page

Idle Current

Idle 

Loss

12VA

S12

25%

≤15%

≤20mA

≤0.50W

51×43×36

300

33

T12

10%

≤15%

≤28mA

≤1.00W

51×43×36

300

71

TL12

10%

20%

18mA

≤0.6W

66×49×25.3

330

81

15VA

S15

25%

≤11%

≤28mA

≤0.70W

58.5×49×40

415

34

T15

10%

≤15%

≤35mA

≤0.70W

51×43×36

300

72

T15H

10%

≤17%

≤25mA

≤0.9W

51×43×43.5

420


M15/ MS15

10%

≤18%

≤4mA

0.4W

60×60×26.3

300

93

H15

10%

17%

25mA

0.9W

51×43×43.5

420


18VA

S18

25%

≤10%

≤28mA

≤0.60W

58.5×49×40

415

35

T18

10%

≤12%

≤40mA

≤1.20W

58.5×49×40

415

73

20VA

SL20

15%

≤18%

≤50mA

≤0.85W

68×55×31

420

38

T20

10%

≤9%

≤45mA

≤0.90W

58.5×49×40

415

74

T20H

10%

≤15%

≤40mA

≤1.7W

58.5×48×44.5

520

75

H20

10%

20%

40mA

1.7W

58.5×48×44.5

520


25VA

M25/ MS25

10%

≤14%

6mA

0.6W

60×60×37.5

430

94

30VA

SL30

15%

≤13%

≤70mA

≤1.25W

68×55×37

540

38

35VA

M35/ MS35

10%

≤12%

8mA

0.8W

72×72×37.5

500

95

40VA

SL40

15%

≤12%

≤65mA

≤1.80W

83.5×70.5×39

760

39

T40D

10%

≤10%

≤45mA

≤2W

81×53×53

750

76

50VA

M50/ MS50

10%

≤10%

10mA

1.0W

82.4×82.4×37.5

650

96

60VA

SL60

15%

≤11%

47mA

≤0.85W

83.5×70.5×48

1075

39

90VA

MS90

15%

7%

5.5mA

1.0W

106×88.5×55

1400

97

110VA

MS110

15%

6%

7.5mA

1.5W

116×98.5×54.5

1840

98

160VA

MS160

15%

5%

9.5mA

2.0W

126×108.5×57.5

2300

100

 

 

 

 

 

 

 