“Argent Angel” SL Series Flat PCB Mount Power Transformers
SL30-1.gif
“Argent Angel” SL Series Flat PCB Mount Power Transformers
Rated Power 3VA, 6VA, 9VA, 10VA, 20VA, 30VA, 40VA
Rated Voltage
① Standard series:
Primary:2×110V±15%-20% 50Hz/60Hz
Secondary:2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V
② Non-standard series: It can be customized based on customer's requirements.
General Technical Specifications for Standard Products:

1.  Features

 The fully-encapsulated printed circuit board can be directly welded and assembled, and has a perfect outline.

 It has a low mounting height, compact structure, and is solid, vibration-proof, moisture-proof, flame-resistant, and has high insulation withstand voltages.;

 It is easy to use and reconfigure, and alternative input/output voltages can be obtained by changing the connections of the primary and/or secondary. 

 It has a built-in temperature protector, making it safer to use.

2.  Ambient Conditions

 Temperature: -25℃+70℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar (650800mmHg approximately).

3.  Insulation Rating: Class F (155)

4.  Safety Features

 Dielectric resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 3750 V (50HZ)/1 min;

 Insulation impact strength: Continuously 20 times impact of 6KV(50HZ)/50μS;

 Fire retardancy: In conformity with UL94-Vo.

5. Safety approval: 

 

6.  Rated Power   3VA, 6VA, 9VA, 10VA, 20VA, 30VA, 40VA

7.  Rated Voltage

 Standard series

Primary2×110V±15%-20%    50Hz/60Hz

Secondary2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V

 Non-standard series: It can be customized based on customer's requirements.

 

8. Universal Technical Parameters of SL Series Standard Product

No.

Model

Output

Power

Idle Current

Idle Loss

Voltage Regulation Ratio

Temperature

Rise

Weight

(g)

Dimension

L×W×H

(mm)3

1

SL3

3VA

12mA

0.25W

25%

20

165

53×43×21.5

2

SL6

6VA

15mA

0.32W

24%

22

220

53×43×25.5

3

SL9

9VA

20 mA

0.43W

23%

25

280

53×43×30

4

SL10

10VA

30 mA

0.75W

26%

30

290

68×55×24

5

SL20

20VA

50 mA

0.85W

18%

35

420

68×55×31

6

SL30

30VA

70 mA

1.25W

13%

40

540

68×55×37

7

SL40

40VA

65 mA

1.8W

12%

45

760

83.5×70.5×39