TAR150 Series Rectangular AC Current Transformer
TAR150系列矩形交流-1.png
TAR150 Series Rectangular AC Current Transformer
Features:
① Vertical core, flexible installation, can be fixed on the busbar or on the bottom plate;
② It can be equipped with various types of busbars, such as flat busbars, round busbars or cables;
③ The output terminal is a screw fastened crimping type standard terminal, which is convenient for wiring at the engineering site;
④ Box structure, closed plastic case, beautiful appearance.
TAR150 General Technical Specifications for Standard Products:

1Features: 

① Vertical core, flexible installation, can be fixed on the busbar or on the bottom plate;

② It can be equipped with various types of busbars, such as flat busbars, round busbars or cables;

③ The output terminal is a screw fastened crimping type standard terminal, which is convenient for wiring at the engineering site;

④ Box structure, closed plastic case, beautiful appearance.


 

2Ambient conditions:

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 8601060mbar

(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

① Insulation resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 3kV~ 10kV 50Hz/1min;

③ Fire retardancy: In conformity with UL94-V0.

 

image.png


6. Outline Drawing, Installation Dimension and Coil Drawing : ( tolerance ± 1mm )

















image.png








● Note: Each product is supplied with two bottom plate feet, one busbar foot and screws for fixing the busbar. See below for installation instructions.

image.png

Installation Instructions:

● When fixing to the bottom plate;

Take the two feet ( supplied with the product ) and insert them into the foot sockets on the bottom plate as shown in Figure 2. The center distance of the mounting holes is 60 × 89 ; the mounting hole diameter of the feet is Φ5.0; the transformer can be fixed on the bottom plate with M5 screws. (Note: Another 6 8 hole spacing mounting plate is optional)

● When fixing to the busbar;

Take two legs with M5 holes ( supplied with the product ) and insert them into the bus bar leg slots as shown in Figure 2. The center distance of the M5 holes is 59, and the transformer can be fixed on the bus bar with M5 screws.

 

7. Typical Application and Performance Parameters:

See the table below for performance parameters when applied as shown in Figure 3.

image.png

 

Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance

R L

Rated

Sampling Voltage

Phase Shift

Non-linearity

Linear Range

 

Withstand Voltage

 

TAR150-01

5000A

5A

5V

≤30'

≤0.5%

2 times of rated value

≥10kV

TAR150-02

4000 A

5A

0.8Ω

4V

≤30'

≤0.5%

2 times of rated value

≥3kV

 

Notes:

a. In practical applications, the sampling resistance should be less than or equal to the Rated value given in the above table, which will improve the nonlinearity and phase shift;

b. If the conversion ratio required by the user is different from the above, it can be customized according to the user's requirements.

 

8Attention:

 Connect the primary of the current transformer in series with the measured current loop, and operate the secondary in near short circuit mode.

 Do not allow the secondary of the current transformer to be open circuited and do not install any fuse on the secondary. 