TA0813 Series Vertical Type Microminiature Pulse Current Transformers
TA0813系列立式穿芯微型脉冲电流互感器-1.gif
TA0813 Series Vertical Type Microminiature Pulse Current Transformers
Features:
① Vertical core-through, printed circuit board directly soldered and installed;
② Small size, high frequency, beautiful appearance;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability .
TA0813系列 General Technical Specifications for Standard Products:

TA0813 Series Vertical Type Microminiature Pulse Current Transformers

LI056V5/2016

1Features:

 Vertical core-through, printed circuit board directly soldered and installed;

 Small size, high frequency, beautiful appearance;


 Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability .

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;


 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

3Operating Frequency Range: 2kHz200kHz

4Insulation Thermal Class: Class B (130)

5Safety Features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6KV 50Hz/1min;


 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram( tolerance±0.3 mm)

 Outline drawing and installation dimensions are shown in Figure 1:

 The coil diagram is shown in Figure 2.

image.png

image.png 

7Typical Application and Technical Parameters:( tolerance±0.3mm )

See the table below for performance parameters when applied as shown in Figure 3

 Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance

Rated

Sampling Voltage

Non-linearity

TA0813-1

20A

100mA

25Ω

2.5V

≤2%

TA0813-2

20A

40mA

125Ω

5V

≤2%

TA0813-3

20A

20mA

500Ω

10V

≤2%

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop. Operate the secondary winding in a near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited. Do not install any fuse on the secondary winding.