LI056V5/2016
1.Features:
① Vertical core-through, printed circuit board directly soldered and installed;
② Small size, high frequency, beautiful appearance;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability .
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 2kHz~200kHz
4.Insulation Thermal Class: Class B (130℃)
5.Safety Features:
① Insulation resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6.Outline Drawing, Installation Dimension and Coil Diagram:( tolerance±0.3 mm)
① Outline drawing and installation dimensions are shown in Figure 1:
② The coil diagram is shown in Figure 2.
7.Typical Application and Technical Parameters:( tolerance±0.3mm )
See the table below for performance parameters when applied as shown in Figure 3
Model | Rated Input Current | Rated Output Current | Rated Sampling Resistance | Rated Sampling Voltage | Non-linearity |
TA0813-1 | 20A | 100mA | 25Ω | 2.5V | ≤2% |
TA0813-2 | 20A | 40mA | 125Ω | 5V | ≤2% |
TA0813-3 | 20A | 20mA | 500Ω | 10V | ≤2% |
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop. Operate the secondary winding in a near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited. Do not install any fuse on the secondary winding.