TA0916 Series Microminiature Precision Pulse Current Transformer with Bus Built-in
TA0916系列母线内置微型脉冲电流互感器-1.gif
TA0916 Series Microminiature Precision Pulse Current Transformer with Bus Built-in
Features:
① The printed circuit board is directly welded and installed, and the appearance is beautiful;
② Small size, high precision; fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable.
TA0916 General Technical Specifications for Standard Products:

1Features:

The printed circuit board is directly welded and installed, and the appearance is beautiful;


Small size, high precision; fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable.

 

2Ambient conditions:

 Ambient temperature: -55℃~+85;

 Relative humidity: 90% at 40;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 2kHz100k Hz

 

4Insulation Thermal Class: Class B (130 )

 

5Safety Features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 2.5KV 50Hz/1min;


 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram : ( tolerance±0.3 mm)

 Outline drawing and installation dimensions are shown in Figure 1:


 The coil diagram is shown in Figure 2:

image.png

   image.png

image.png

7Typical Application and Technical Parameters:( tolerance±0.3mm )

When the sampling voltage is directly obtained by the resistance method (as shown in Figure 3 ) , the performance parameters are shown in the table below .

Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance RL

Rated

Sampling Voltage

Non-linearity

Linear Range

TA0916-01

2A

4mA

1000Ω

4V

≤2%

≥1.5 times of the rated value

TA0916-02

2A

2mA

4000Ω

8V

≤1.5%

≥2 times of the rated value

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop. Operate the secondary winding in a near short-circuit mode.